Atnaujintas knygų su minimaliais defektais pasiūlymas! Naršykite ČIA >>

Automatic Detection of Rib Contours in Chest Radiographs: An Application of Image Processing Techniques in Medical Diagnosis

-15% su kodu: ENG15
71,98 
Įprasta kaina: 84,68 
-15% su kodu: ENG15
Kupono kodas: ENG15
Akcija baigiasi: 2025-03-03
-15% su kodu: ENG15
71,98 
Įprasta kaina: 84,68 
-15% su kodu: ENG15
Kupono kodas: ENG15
Akcija baigiasi: 2025-03-03
-15% su kodu: ENG15
2025-02-28 84.6800 InStock
Nemokamas pristatymas į paštomatus per 11-15 darbo dienų užsakymams nuo 20,00 

Knygos aprašymas

1.1 Statement of the Problem This work describes a new and effective computer algorithm for detecting the contours of ribs in ehest radiographs. The problem, which is common to both the research areas of Machine Vision and Biomedical Computing, is to extract graphical information, such as that represented in Figure 1-lb, from a picture such as Figure 1-la. Figure 1-la shows a typical posterior-anterior (PA) ehest radiograph while Figure 1-lb shows a drawing of the ventral aspect of the thorax. lt is hoped that this researchwill contribute significantly toward developing an automated system for interpreting ehest radio­ graphs. 1.2 Why Have We Carried Out This Research? Since about one-third of the 650,000,000 medical radiographs (X-ray photographs) taken annually in the United States areehest radiographs, there is a growing awareness of the need for a computer­ aided system to help diagnose these radiographs. The detection of rib contours is, of course, a necessary element in such a system. In addition to being able to accommodate the need for a mass screening program, an automated systemalso has the ability to detect anomalies at earlier stages. Ziskin et al (1971) state that reliable 2 {a) Original Chest Radiograph Figure 1-1. A Chest Radiograph 3 VENTRAL CONTOUR CARTILAGE {b) THE THORAX; VENTRAL ASPECT OF A CHEST RADIOGRAPH Figura 1-1 A CHEST RADIOGRAPH studies indicate that even under routine conditions radiologists fail to detect approximately 30% of abnormalities in ehest X-ray films.

Informacija

Autorius: Wechsler
Serija: Interdisciplinary Systems Research
Leidėjas: Birkhäuser Basel
Išleidimo metai: 1977
Knygos puslapių skaičius: 148
ISBN-10: 3764308877
ISBN-13: 9783764308872
Formatas: 235 x 155 x 9 mm. Knyga minkštu viršeliu
Kalba: Anglų

Pirkėjų atsiliepimai

Parašykite atsiliepimą apie „Automatic Detection of Rib Contours in Chest Radiographs: An Application of Image Processing Techniques in Medical Diagnosis“

Būtina įvertinti prekę